mirror of
https://github.com/tinygo-org/tinygo.git
synced 2026-08-05 03:27:48 +00:00
rp2: use the correct channel mask for rp2350 ADC; hold lock during read (#4938)
This commit is contained in:
@@ -73,14 +73,15 @@ func (c ADCChannel) Configure(config ADCConfig) error {
|
||||
func (c ADCChannel) getOnce() uint16 {
|
||||
// Make it safe to sample multiple ADC channels in separate go routines.
|
||||
adcLock.Lock()
|
||||
rp.ADC.CS.ReplaceBits(uint32(c), 0b111, rp.ADC_CS_AINSEL_Pos)
|
||||
rp.ADC.CS.ReplaceBits(uint32(c)<<rp.ADC_CS_AINSEL_Pos, rp.ADC_CS_AINSEL_Msk, 0)
|
||||
rp.ADC.CS.SetBits(rp.ADC_CS_START_ONCE)
|
||||
|
||||
waitForReady()
|
||||
v := rp.ADC.RESULT.Get()
|
||||
adcLock.Unlock()
|
||||
|
||||
// rp2040 is a 12-bit ADC, scale raw reading to 16-bits.
|
||||
return uint16(rp.ADC.RESULT.Get()) << 4
|
||||
return uint16(v) << 4
|
||||
}
|
||||
|
||||
// getVoltage does a one-shot sample and returns a millivolts reading.
|
||||
|
||||
Reference in New Issue