runtime/esp32c6: select 80MHz PLL as TIMG0 timer clock source

The shared timekeeping code assumes the TIMG0 timer counts at 40MHz,
but on the ESP32-C6 the timer clock defaults to the 40MHz XTAL, giving
a 20MHz tick with the /2 prescaler and making all delays run twice as
long. Select PLL_F80M (80MHz) and enable the timer group clock so the
25ns/tick assumption holds.

Signed-off-by: deadprogram <ron@hybridgroup.com>
This commit is contained in:
deadprogram
2026-07-07 20:26:11 +02:00
committed by Ron Evans
parent 9e9f1d0b96
commit 3ad913acb8
+17
View File
@@ -58,6 +58,23 @@ func main() {
// Switch to PLL: SOC_CLK_SEL = 1 (SPLL), HS_DIV_NUM = 2 (div3).
esp.PCR.SYSCLK_CONF.Set(1<<16 | 2<<8)
// Select the Timer Group 0 timer clock source.
//
// The shared timekeeping code (runtime_esp32xx.go) assumes the TIMG0 timer
// counts at 40MHz: an 80MHz source divided by the prescaler of 2 set in
// initTimer, giving 25ns/tick. On the ESP32-C6 the timer group timer clock
// is not the APB clock; it is selected via PCR and defaults to the 40MHz
// XTAL (TG0_TIMER_CLK_SEL = 0). With the /2 prescaler that yields a 20MHz
// tick, so every delay would be twice as long as intended (time.Sleep and
// therefore blinky run at half speed).
//
// Select PLL_F80M (80MHz) as the source so the timer counts at 40MHz and
// the 25ns/tick assumption holds. Clock source encoding (esp-idf
// timer_ll_set_clock_source): 0 = XTAL, 1 = PLL_F80M, 2 = RC_FAST.
esp.PCR.SetTIMERGROUP0_CONF_TG0_CLK_EN(1)
esp.PCR.SetTIMERGROUP0_TIMER_CLK_CONF_TG0_TIMER_CLK_SEL(1)
esp.PCR.SetTIMERGROUP0_TIMER_CLK_CONF_TG0_TIMER_CLK_EN(1)
clearbss()