Files
Pat Whittingslow 5cb360a4bf Add Honeywell HSC TruStability SPI+I2C pressure sensor driver (#799)
* add honeywell pressure sensor
* apply @aykevl suggestions
2025-11-08 10:45:18 +01:00

50 lines
1.2 KiB
Go

package main
import (
"machine"
"time"
"tinygo.org/x/drivers"
"tinygo.org/x/drivers/honeyhsc"
)
// Data taken from https://github.com/rodan/honeywell_hsc_ssc_i2c/blob/master/hsc_ssc_i2c.cpp
// these defaults are valid for the HSCMRNN030PA2A3 chip
const (
i2cAddress = 0x28
// 10%
outputMinimum = 0x666
// 90% of 2^14 - 1
outputMax = 0x399A
// min is 0 for sensors that give absolute values
pressureMin = 0
// 30psi (and we want results in millipascals)
// pressureMax = 206842.7
pressureMax = 206843 * 1000
)
func main() {
bus := machine.I2C0
err := bus.Configure(machine.I2CConfig{
Frequency: 400_000, // 100kHz minimum and 400kHz I2C maximum clock. 50 to 800 for SPI.
SDA: machine.I2C0_SDA_PIN,
SCL: machine.I2C0_SCL_PIN,
})
if err != nil {
panic(err.Error())
}
sensor := honeyhsc.NewDevI2C(bus, i2cAddress, outputMinimum, outputMax, pressureMin, pressureMax)
for {
time.Sleep(time.Second)
const measuremask = drivers.Pressure | drivers.Temperature
err := sensor.Update(measuremask)
if err != nil {
println("error updating measurements:", err.Error())
continue
}
P := sensor.Pressure()
T := sensor.Temperature()
println("pressure:", P, "temperature:", T)
}
}