//go:build tinygo
// Package dht provides a driver for DHTXX family temperature and humidity sensors.
//
// [1] Datasheet DHT11: https://www.mouser.com/datasheet/2/758/DHT11-Technical-Data-Sheet-Translated-Version-1143054.pdf
// [2] Datasheet DHT22: https://cdn-shop.adafruit.com/datasheets/Digital+humidity+and+temperature+sensor+AM2302.pdf
// Adafruit C++ driver: https://github.com/adafruit/DHT-sensor-library
package dht // import "tinygo.org/x/drivers/dht"
import (
"machine"
"time"
)
// Celsius and Fahrenheit temperature scales
type TemperatureScale uint8
func (t TemperatureScale) convertToFloat(temp int16) float32 {
if t == C {
return float32(temp) / 10
} else {
// Fahrenheit
return float32(temp)*(9.0/50.) + 32.
}
}
// All functions return ErrorCode instance as error. This class can be used for more efficient error processing
type ErrorCode uint8
const (
startTimeout = time.Millisecond * 200
startingLow = time.Millisecond * 20
C TemperatureScale = iota
F
ChecksumError ErrorCode = iota
NoSignalError
NoDataError
UpdateError
UninitializedDataError
)
// error interface implementation for ErrorCode
func (e ErrorCode) Error() string {
switch e {
case ChecksumError:
// DHT returns ChecksumError if all the data from the sensor was received, but the checksum does not match.
return "checksum mismatch"
case NoSignalError:
// DHT returns NoSignalError if there was no reply from the sensor. Check sensor connection or the correct pin
// sis chosen,
return "no signal"
case NoDataError:
// DHT returns NoDataError if the connection was successfully initialized, but not all 40 bits from
// the sensor is received
return "no data"
case UpdateError:
// DHT returns UpdateError if ReadMeasurements function is called before time specified in UpdatePolicy or
// less than 2 seconds after past measurement
return "cannot update now"
case UninitializedDataError:
// DHT returns UninitializedDataError if user attempts to access data before first measurement
return "no measurements done"
}
// should never be reached
return "unknown error"
}
// Update policy of the DHT device. UpdateTime cannot be shorter than 2 seconds. According to dht specification sensor
// will return undefined data if update requested less than 2 seconds before last usage
type UpdatePolicy struct {
UpdateTime time.Duration
UpdateAutomatically bool
}
var (
// timeout counter equal to number of ticks per 1 millisecond
timeout counter
)
func init() {
timeout = cyclesPerMillisecond()
}
func cyclesPerMillisecond() counter {
freq := machine.CPUFrequency()
freq /= 1000
return counter(freq)
}