sx127x: Driver for Semtech sx127x radio modules

This first version of the driver has been tested with BB-FRM9x module
This commit is contained in:
Olivier Fauchon
2021-01-19 00:35:45 +01:00
committed by deadprogram
parent 877342d0ff
commit 67d2af5d45
6 changed files with 1158 additions and 0 deletions
+124
View File
@@ -0,0 +1,124 @@
package main
// This example code enable continuous Wave/Preamble
import (
"machine"
"time"
"tinygo.org/x/drivers/sx127x"
)
const (
FREQ = 868100000
)
var (
loraRadio *sx127x.Device
// We assume the module is connected this way:
SX127X_PIN_RST = machine.PB9
SX127X_PIN_CS = machine.PB8
SX127X_PIN_DIO0 = machine.PA0
SX127X_SPI = machine.SPI0
)
func main() {
println("\n# TinyGo Lora continuous Wave/Preamble test")
println("# -----------------------------------------")
machine.LED.Configure(machine.PinConfig{Mode: machine.PinOutput})
// SPI, RESET, CS configuration
SX127X_PIN_RST.Configure(machine.PinConfig{Mode: machine.PinOutput})
SX127X_PIN_CS.Configure(machine.PinConfig{Mode: machine.PinOutput})
SX127X_PIN_DIO0.Configure(machine.PinConfig{Mode: machine.PinInputPulldown}) // Checkthat
SX127X_SPI.Configure(machine.SPIConfig{Frequency: 500000, Mode: 0})
// Create the driver
loraRadio = sx127x.New(SX127X_SPI, SX127X_PIN_CS, SX127X_PIN_RST)
err := SX127X_PIN_DIO0.SetInterrupt(machine.PinRising, func(machine.Pin) {
loraRadio.HandleInterrupt()
})
if err != nil {
panic("Can't configure DIO int handler")
}
// Reset the radio module
loraRadio.Reset()
println("Try to detect sx127x radio")
state := loraRadio.DetectDevice()
if !state {
panic("sx127x not detected. ")
} else {
println("sx127x detected")
}
/*
// Prepare for Lora operation
loraConf := sx126x.LoraConfig{
Freq: FREQ,
Bw: sx126x.SX126X_LORA_BW_500_0,
Sf: sx126x.SX126X_LORA_SF9,
Cr: sx126x.SX126X_LORA_CR_4_7,
HeaderType: sx126x.SX126X_LORA_HEADER_EXPLICIT,
Preamble: 12,
Ldr: sx126x.SX126X_LORA_LOW_DATA_RATE_OPTIMIZE_OFF,
Iq: sx126x.SX126X_LORA_IQ_STANDARD,
Crc: sx126x.SX126X_LORA_CRC_ON,
SyncWord: sx126x.SX126X_LORA_MAC_PRIVATE_SYNCWORD,
LoraTxPowerDBm: 14,
}
loraRadio.LoraConfig(loraConf)
*/
println("Start Configure Lora")
loraRadio.SetOpModeLora()
loraRadio.SetOpMode(sx127x.SX127X_OPMODE_SLEEP)
loraRadio.SetTxPower(11, true)
loraRadio.SetFrequency(FREQ)
loraRadio.SetBandwidth(sx127x.SX127X_LORA_BW_125_0)
loraRadio.SetCodingRate(sx127x.SX127X_LORA_CR_4_5)
loraRadio.SetRxPayloadCrc(sx127x.SX127X_LORA_CRC_ON)
loraRadio.SetHeaderMode(sx127x.SX127X_LORA_HEADER_EXPLICIT)
loraRadio.SetLowDataRateOptim(sx127x.SX127X_LOW_DATARATE_OPTIM_OFF)
println("End Configure Lora")
for {
loraRadio.TxLora([]byte("Hello"))
machine.LED.Set(!machine.LED.Get())
time.Sleep(time.Second * 2)
}
/*
// Although LoraConfig has already configured most of Lora settings,
// the following lines are still required to enable Continuous Preamble/Wave
loraRadio.SetPacketType(sx126x.SX126X_PACKET_TYPE_LORA)
loraRadio.SetRfFrequency(loraConf.Freq)
loraRadio.SetModulationParams(loraConf.Sf, loraConf.Bw, loraConf.Cr, loraConf.Ldr)
loraRadio.SetTxParams(loraConf.LoraTxPowerDBm, sx126x.SX126X_PA_RAMP_200U)
for {
println("2 seconds in Continuous Preamble")
loraRadio.SetStandby()
loraRadio.SetTxContinuousPreamble()
time.Sleep(2 * time.Second)
println("Continuous Preamble Stopped")
loraRadio.SetStandby()
time.Sleep(10 * time.Second)
println("2 seconds in Continuous Wave")
loraRadio.SetTxContinuousWave()
time.Sleep(2 * time.Second)
println(" Continuous Wave Stopped")
loraRadio.SetStandby()
time.Sleep(60 * time.Second)
}
*/
}