Fixed bug in aht20 driver
This commit is contained in:
committed by
Ron Evans
parent
17f273243d
commit
00578a3a81
+2
-2
@@ -29,7 +29,7 @@ func New(bus drivers.I2C) Device {
|
||||
func (d *Device) Configure() {
|
||||
// Check initialization state
|
||||
status := d.Status()
|
||||
if status&0x08 == 1 {
|
||||
if status&STATUS_CALIBRATED == 1 {
|
||||
// Device is initialized
|
||||
return
|
||||
}
|
||||
@@ -69,7 +69,7 @@ func (d *Device) Read() error {
|
||||
}
|
||||
|
||||
// If measurement complete, store values
|
||||
if data[0]&0x04 != 0 && data[0]&0x80 == 0 {
|
||||
if data[0]&STATUS_CALIBRATED != 0 && data[0]&STATUS_BUSY == 0 {
|
||||
d.humidity = uint32(data[1])<<12 | uint32(data[2])<<4 | uint32(data[3])>>4
|
||||
d.temp = (uint32(data[3])&0xF)<<16 | uint32(data[4])<<8 | uint32(data[5])
|
||||
return nil
|
||||
|
||||