Every logger call in the automation module was a failure path, so a working automation and a misconfigured one looked identical: nothing happened either way, as far as the user could see. Two channels, because they answer different questions. A new AUTOMATION log origin says what happened and when. A coalesced socket message feeds a "last fired" column in the panel, which answers whether an automation is alive at all: one that stays blank while its neighbours tick is the clearest sign that a filter or a trigger is wrong. Flood control is the whole difficulty here. onClock fires every second and the logger queue holds 100 entries, so per-fire logging on a continuous lifecycle would evict everything else within two minutes. Those cycles log a single notice per load explaining the silence and nothing after; the rest dedupe inside a one second window so a rapid reload does not spam. The socket message still goes out for continuous cycles, throttled to once a second, because the panel needs it to show the automation is running. Log.tsx carried six copies of the same twelve line button. Adding a seventh origin was the moment to collapse them, so the next one is free. The client log store was also unbounded while the server queue is capped; it now holds 500 entries. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LpbLJVVT26tzWkduck1M9H